REGENT ESTATES WOULD
LIKE TO PRESENT TO ALL LANDLORDS SAFETY GUIDELINES.
THE CONSUMER PROTECTION
ACT 1987 - SAFETY
THE TYPES OF GOODS
INVOLVED INCLUDE:
- PORTABLE
ELECTRICAL EQUIPMENT AND PLUGS
- UPHOLSTERED
FURNITURE
- GAS
COOKERS
SAFETY PROVISIONS ALSO APPLY TO
- FIREGUARDS
- CARRYCOT
STANDS
- BUNK
BEDS
- TOYS
- OTHER
GAS APPLIANCE
THERE ARE DETAILED SAFETY REQUIREMENTS WHICH APPLY TO THE ITEMS ALREADY
MENTIONED. BELOW, HOWEVER, THIS IS A BRIEF GUIDE TO LIKELY PROBLEMS WHICH
MAY BE FOUND AND THE SAFETY REQUIREMENTS.
ELECTRICAL SAFETY - PROBLEMS TO LOOK FOR:
- FRAYED
OR DAMAGED CABLES
- OLD
APPLIANCES WITH METAL PARTS AND NO EARTH
- DAMAGE
ALLOWING ACCESS TO LIVE PARTS
- FIREGUARD
OPENINGS WHICH ALLOW ACCESS TO THE ELEMENTS -MAXIMUM GAP IS 25 X 12 MM,
OR 50 X 20 MM FOR SILICON COVERED ELEMENTS
- LAMP
SOCKETS WITH NO SHIELDING FOR THE METAL PART OF THE BULB
- LOOSE
OR WORN CONNECTIONS -E.G. KETTLE SOCKETS OVERHEATING
- INCORRECT
FUSES
- INCORRECT
PLUGS (METAL PINS SHOULD BE SLEEVED)
- CORD
GRIP INOPERATIVE.
UPHOLSTERED FURNITURE
SINCE 1 MARCH 1993, SECOND HAND FURNITURE MUST PASS THE FIRE SAFETY TESTS
APPLICABLE TO NEW FURNITURE. FURNITURE WHICH COMPLIES WILL BE LABELLED WITH
A PERMANENT LABEL WITH THE WORDS “CARELESSNESS CAUSES FIRE “ A BATCH
NUMBER AND AN INDICATION THAT THE UPHOLSTERY WITH THE REGULATIONS.
MOST COMPLYING FURNITURE MAY CONTINUE TO BE SUPPLIED IN LET ACCOMMODATION
PRIOR TO 1 MARCH 1993. ANY REPLACEMENT OR ADDITIONAL UPHOLSTERED FURNITURE
PUT INTO LET ACCOMMODATION MUST COMPLY WITH THE SAFETY REGULATIONS.
GAS COOKERS - SAFETY REQUIREMENTS INCLUDE
- SEALED
OVEN DOORS TO PREVENT ESCAPE OF GAS
- ANY
BURNER IGNITING DEVICE MUST IGNITE PROMPTLY
- TAPS
OR HANDLES SO DESIGNED TO ENSURE THAT THEY CANNOT BE TURNED ON ACCIDENTALLY
- OPERATING
INSTRUCTIONS - EITHER ON THE APPLIANCE OR IN A BOOKLET
- INSTRUCTIONS
MARKED ON TAP HANDLES INDICATING WHICH TAP CONTROLS WHICH BURNER AND THE
RELEVANT CONTROL POSITIONS FOR EACH TAP
- A WARNING
AGAINST CLOSING LID BEFORE BURNERS ARE EXTINGUISHED - ALTHOUGH THIS DOES
NOT APPLY WHERE THE LID AUTOMATICALLY SHUTS OFF THE BURNERS.
GAS SAFETY
THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1994 ARE ENFORCED BY THE
HEALTH AND SAFETY EXECUTIVE-WHICH IS RESPONSIBLE FOR ALL PROSECUTIONS UNDER
THE ACT- AND CAME INTO EFFECT ON 31 OCTOBER 1994. THE MAIN PROVISIONS ARE
AS FOLLOWS:
- ONLY
CORGI REGISTERED FITTERS MAY BE USED TO WORK ON GAS PIPES OR APPLIANCES
(DIY WORK IS NOT PERMITTED UNDER ANY CIRCUMSTANCES)
- OWNERS
ARE REQUIRED TO ENSURE THAT ALL GAS APPLIANCES ARE SAFE
- AMONGST
OTHER THINGS, THEY MUST ENSURE THAT A CORGI INSPECTION IS CARRIED OUT ANNUALLY.
- A RECORD
MUST BE KEPT OF ALL INSPECTIONS (INCLUDING THE DATE OF INSPECTION AND DETAILS
OF ANY DEFECTS IDENTIFIED AND THE REMEDIAL ACTION TAKEN) AND BE AVAILABLE
ON REQUEST.
- ANY
UNSAFE APPLIANCES MUST BE DISCONNECTED
- A RESTRICTION
IS IMPOSED ON THE SIZE AND TYPE OF APPLIANCE PERMITTED IN BATHROOMS AND
BEDROOMS.
|